<link href="https://fonts.googleapis.com/css2?family=Roboto:wght@300;400;500&display=swap" rel="stylesheet">
DLISData QualityFile FormatQC

The Parameters Your LAS File Leaves Behind: DLIS Acquisition Parameters and Data Quality

A DLIS file can hold hundreds of acquisition parameters: bit size, mud resistivities, temperatures, tool positions. Most DLIS to LAS conversions keep one copy of each, or none. Here is what goes wrong with them, from per-tool copies to placeholder values written as depths, and what PetroCurve does about it.

PetroCurve Team5 min read

Part 3 of our series on DLIS and LIS. Part 1 covered reading both formats; Part 2 covered what goes wrong in LIS files.

Curves get all the attention in a well log. The parameters are what make them interpretable. Bit size tells you whether the caliper is reading washout. Mud and mud filtrate resistivities, and the temperatures they were measured at, go into every water saturation calculation. Tool positions say whether a density tool was pressed against the borehole wall or hanging free.

In a DLIS file these are first-class objects, often hundreds of them. The Schlumberger wireline file 206_05a-_3_DWL_DWL_WIRE_258276498.DLIS from the dlisio test corpus holds 226 parameters for two tools. When the file becomes LAS, they have one place to go, the ~Parameter section, and that section can hold one value per name. What happens on the way there is a data quality problem nobody sees, because the result looks complete.

Why DLIS Parameters Do Not Fit

A DLIS parameter is an object with a name, a long name, units, one or more values, and links to the tools and zones it applies to. Several things a DLIS file does routinely have no equivalent in LAS:

  • Several copies of one name. DLIS identifies an object by its origin and copy number as well as its name, so TPOS can appear once per tool, each copy a different object with its own value.
  • Values per zone. A parameter can hold one value per depth zone: a mud weight that changed partway down the hole, for example.
  • Arrays. A value can be a list rather than a single number.
  • Absent values. A parameter can be declared with a placeholder that means "not set".
  • Vendor display settings. Some acquisition systems store channel display settings as parameters named after the channel, which then look like real parameters such as BS.

A converter has to decide what to do with each case. Most decide by default, and do not say what they decided.

Copies That Belong to Different Tools

One of our test files, a wireline log from the Kiel-Windeweer field, holds five copies of TPOS, the tool position, each belonging to a tool in the string. They hold two different values: Eccentered for the H4TG tool and Free Hanging for the HACRT tool. Both are correct. They describe different tools.

A converter that keys parameters on their name alone keeps one of the two values and drops the other, or keeps the first and reports four "conflicts" that are not conflicts at all. Either way, the LAS file now says one thing about a tool string that did two.

What PetroCurve does: when every copy of a parameter names its tool, and no tool holds two different values, each value is written on its own line with the tool in the name and the description: TPOS_H4TG and TPOS_HACRT, with the long name followed by the tools that hold that value. Nothing is lost, and every line still has a unique name, so the file stays valid LAS 2.0.

Copies That Really Disagree

The same file also holds RMIN twice for one tool, once as 0.2 and once as 200. That is a real conflict. One of them is probably a unit or scaling error, and nothing in the file says which.

What PetroCurve does: it does not pick silently. The first value is written to ~Parameter. Every copy, with its value, units and source, goes into the receipt that comes with the LAS file, and the file's ~Other section says how many parameters had conflicting values. Whoever uses the file can see the disagreement and resolve it from the job's paperwork.

Placeholders Written as Depths

DLIS files often declare a parameter with a value that means "not set": -999.25, the same value LAS uses for a missing reading. A converter that copies values blindly writes the placeholder into the LAS file as if it were data.

For most parameters that is merely confusing. For depth parameters it is dangerous. TLI, the top log interval, written as -999.25 ft reads as a real depth, almost a thousand feet above the surface. Software that reads ~Parameter to set the logged interval, or a person skimming the header, takes it at face value.

What PetroCurve does: its DLIS reader marks a parameter whose values are all absent, and PetroCurve writes it with a blank value, so the name and description survive but no false number does, and lists it in ~Other and in the receipt: "Parameters that hold only absent values, written blank: TLI."

What Else Travels With the Parameters

The parameters are not the only part of the object model a conversion has to handle:

  • Remarks. The field engineer's free text, stored as numbered parameters (R1, R2, …) in many files. PetroCurve writes each one to ~Other as Remark 1: …, in order, instead of leaving them as cryptic parameters. The 206/05a file has three, the Kiel-Windeweer file five.
  • Well location. Country, field location lines, latitude and longitude come from the file's well header and are written to ~Well as CTRY, LOC, LOC1, LOC2, LATI and LONG.
  • Vendor display parameters are left out of ~Parameter so they cannot shadow a real parameter of the same name, and the receipt lists them.
  • Encrypted records and vendor-private sets cannot be read by anyone without the vendor's software. The 206/05a file has 11 encrypted records and 5 private sets. PetroCurve counts them and lists them as not converted, so you know they exist.

Why This Is a QC Problem, Not Just a Format Problem

None of this stops a LAS file from loading. That is exactly why it matters. A density log whose tool position was lost, a saturation calculation using the wrong of two RMIN values, a log interval starting at -999.25 ft: each produces a plausible answer that is wrong, and nothing downstream flags it.

The fix is not a cleverer converter that guesses better. It is a conversion that writes down what it did. PetroCurve's receipt, the ~Other summary in the LAS file, and the QC report from Review data together record:

  • every parameter written, renamed per tool, written blank, or left out, and why,
  • every conflict, with all the values,
  • every curve renamed, dropped as an exact copy, or found to hold no data,
  • and every decision made in Review data afterwards.

The next person to open the file can see what happened to it without asking you.

Try It on Your Own Files

Open a DLIS file in the inspector. The Parameters tab shows every parameter with its tool. Download LAS gives you the LAS 2.0 file with the receipt next to it. Open the data set in the viewer and run Review data to check depth, datum, values and names before it goes anywhere else.


PetroCurve checks LAS, DLIS and LIS well logs in your browser and converts DLIS and LIS to LAS 2.0 with a receipt of everything that changed or did not fit. Your data never leaves your device. Open a DLIS file →

More posts

LISData QualityFile FormatQC

What Goes Wrong in LIS Files, and How to Catch It Before It Reaches Your Model

LIS files from the 1970s to the 1990s still hold a large share of the world's well log data. Here is what goes wrong in them: tape-image wrapping, damaged records, curves that hold nothing, missing depth references, four-character names and index set-ups a LAS file cannot express. And what PetroCurve checks for each.

DLISLISFile FormatProduct

DLIS and LIS in PetroCurve: Open, Inspect, Plot and Convert to LAS in Your Browser

PetroCurve now reads DLIS and LIS, the two binary well log formats almost no free tool can open. See every curve, tool, parameter and remark in the file, plot any log data set in the viewer, and convert it to LAS 2.0 with a receipt of everything that did not fit. Nothing is installed and nothing is uploaded.

LASFile FormatPetrophysics

The Complete Guide to LAS File Format: Structure, Versions, and Common Pitfalls

Everything you need to know about LAS files: how the format is structured, how the three versions differ, where real files deviate from the spec, and what to do about it.